Troubleshooting
Siren
Siren does not respond to arming or disarming
•Sirenbatteriesarecompletelyexhausted.
Check siren batteries by removing siren cover, if
there is no tamper alarm when removed, replace
batteries with new alkaline equivalents.
•Sirennotlearnt-in.Ifsirenproducesatamper
alarm when the cover is removed and siren is OK,
learn-in the siren.
•Sirenoutofrange.
Siren produces a 3 second alarm when
disarmed
•Therehasbeenapreviousalarmandtheremight
be an intruder still in the premises.
Siren produces a series of pips when armed or
disarmed
•Thesirenhaslowbatteries.Checkthatthe
siren produces a series of pips when arming
and disarming, indicating low batteries. Change
batteries with new alkaline replacements.
•Thesirentamperswitchhasbeendisturbed.
Check that the siren produces a series of pips only
when arming, indicating a tamper fault. Check that
the siren cover is firmly secured and the tamper
switch plunger is in contact with the wall. If not use
suitable packing material to fill gap.
Siren produces an interrupted tone when
sounding an alarm
•Thesirenhaslowbatteries.Changebatterieswith
new alkaline replacements.
_____________________________________________
PIR
PIR does not respond to movement
•PreviousmovementhastriggeredthePIRsleep
timer and is preventing subsequent movement
detection. Arm system and vacate protected room
for at least 1.5 minutes before testing.
PIR is slow to respond
•Thisisnormal,thePIRhassophisticatedfalse
alarm filtering that will filter out random fluctuations
and responds to genuine movement across field of
view, it is less sensitive walking directly towards it.
PIR gives false alarms
•Checkpetshavenoaccesstoprotectedarea.
•CheckthatPIRisnotpointedatsourcesofheator
moving objects, e.g. fluttering curtains.
•CheckthatPIRisnotmountedaboveconvector
heaters or pointing directly at windows.
PIR LED flashes
•Batteriesareloworthetamperswitchisdisturbed.
Check that the tamper switch spring is making
contact with base. If the tamper switch is OK,
change batteries with new alkaline replacements.
PIR does not respond to movement
•Batteriesarecompletelyexhausted.Change
batteries with new alkaline replacements, LED will
flash for 30 seconds while components initialise.
_____________________________________________
Door contact
Door contact LED lights up
•Batteriesareloworthetamperswitchdisturbed.
Check that the tamper switch spring is making
contact with the mounting surface. If the tamper
switch is OK, change batteries with new CR2032
coin cell replacements.
Door contact does not respond to door
opening when jumper is in test position
•Batteriesarecompletelyexhausted.Change
batteries with new CR2032 coin cell replacements.
•Themagnetistoofarawayfromthedoorcontact.
Check that the gap between door contact and
magnet is not greater than 8mm.
_____________________________________________
Control unit
User PIN code is not accepted by the control
unit.
•Donotpauseformorethan5secondsinbetween
pressing the keys on the keypad.
•Incorrectcodeentered.Re-enterthecorrectPIN
code.
•Resetsettings-see‘ResetProcedure’and
reprogram the system.
_____________________________________________
Voice - Dialler not responding to alarm
•Checkthetelephonelineisconnectedand
that the correct telephone numbers have been
programmed.